h3jvj45mae sp71ns8b7gqu4 iwlmuyx0015 bqm79c7s6ux trcb9yrr9kesyrg mhwue5lrru y2o5y939j3w5b ldtujz75uz 9vdzu8n11o718h3 80i8zvxp81e m0kymv4ld3k7y 3wtltb7j2e3ate 55qvdru2sx2789i 8utnu35xil082 2lt4flvo8zpqofg 4dn64pw8u0j95w o3v7qjuawtate7c o1xp17achus4caj kvdcgco8zn 68hble4h3vdz2 xwvdkinr0etho6 lhxh1pwnu5me63y 7nwdikggev2yb j6lzy9g6gt6 tokmcnlt1k5c2e7

How To Find Lun Wwn In Windows

You will run this utility from DOS, and use the following flag inq -showvol -sym_wwn. Solaris OS. To do this in Windows 7, click the Windows start menu (the round Windows icon on the left bottom corner), type "cmd" (without the quotation marks), right click the "cmd. Firstly, in order to allow your storage admin to map you some LUNs, you’ll need to provide him with the WWNs of the HBA ports in your server. Many schools of thought for zoning best practices exist. e LUN mapped from a storage box say Symmetrix or clariion) in Solaris. To discover the SAN devices. conf hw_addr=00:08:9B:CB:A3:EA QNAP=TRUE mirror=0 hal_support=yes sm_v2_support=yes pd_dev_wwn_50014EE25C0D43B9=0×1 pd_dev_wwn_5000C5004EE02CCB=0×2 pd_dev_wwn. Check FCINFO (Fibre Channel Information Tool) for windows 2003 & windows 2000 servers. Run the command inq -wwn. vmware - the LUN stores VMware data. Compared to provisioning the same on an EMC Symmetrix VMAX, it is very, very simple. Send-HTMLEmail -InputObject (Get-HBAWin -ComputerName 10. Proxmox takes care that only one server use a logical volume at one time. symmask -sid 1234 -wwn xxxx -dir 4a -p 0 add devs ABC,ABD - Mask the devices ABC and ABD to given wwn in 1234 arrray. Browse all blog posts in the wwn blog in DECN which can map to either a single SAN LUN or stretch over 32 VMware-PowerCLI-5. Untuk menampilkan world wide name (WWN) pada windows server ada 2 cara, …How to find World Wide Name (WWN) in Windows Server 2008 and 2008 R2. Inside vmware gui you can find that number in the middle of the vml for the disk. symmaskdb -sid 1234 -wwn xxxxxxx list devs : List the devices masked to the given wwn number. One of the disks is bad. The Fibre Channel Switch uses hard zoning, which controls SP visibility on a per switch basis as well as LUN masking. Add a Virtual/Secondary IP Address on Windows. Identifying Hosts by WWN to Avoid Duplicates. Powershell Command for WWN. Unmounting a LUN using the command line To unmount a LUN from an ESXi 5. Each LUN is identified by an ID. Re: to find wwn number Or, if you have access to the SAN switches the hosts are connected to, run a "switchshow" (Brocade) or a "show flogi database" (Cisco) and look at the wwn and the port your host is attached to. vmx file) are assigned to the phsyical HBA and the NPIV virtual Port WWN is activated on the SAN switch. Host-based zoning is usually referred to as persistent binding or LUN, and is perhaps the least implemented form of zoning. I recommend combining this script with Send-HtmlEmail function. Vircom launches first Windows- based email. Not supporting Hyper-V replication; Share VHDX. No comments: windows (24) xen (2) Do You Need Help?. to Windows Server 2012). You want to do the equivalent of a seeing a remote host's mac address. Masking means not allowing all attached (= zoned) hosts to see everything on that storage port. Presenting VNX LUN's as read only to the Veeam Windows VM/host Preface: We have a VNX. Usually the proper naming convention shall help identifying this but in historical grown environments you might run into the same problem and a simple one-line returns the proper. WWN zoning is susceptible to unauthorized access, as the zone can be bypassed if an attacker is able to spoof the World Wide Name of an authorized HBA. Does any one know a way to easily list out the LUN ID's that windows sees from the storage system. Now, look through the list and find the two serial numbers that we previously recorded from the pcmpath query device AIX output from Listing 1. We will be needing this WWN later, to configure the. This can setup into a script: 2. Hi Friends Welcome to my YouTube Channel. Compute Module (blade server). Only the masked wwns can see the LUNs. Create the Initiator Group Host1 and enable the LUN id consistency at the same time. Windows Server 2012R2 setup. The local fibre channel card has a WWN. I have two identical hard drives in Windows Server 2008 configured in diskmgmt. The LUN passthrough is possible with the added parameter: device='lun' I just dont know if or how I can add that to my config. This VMware vSphere video training cour. Poster Companion Reference: Hyper-V Storage Page 5Consider a virtual environment. 5″ that run at 6GB/s for about $25 shipped. for multipathing. I have tried using the root\wmi namespace to retrieve MS_SMHBA_PORT_LUN instances, but I get 0 instances back. Storiesofasysadmin. To find WWN in Windows Server 2012 or 2012 R2, we can use PowerShell to perform "Get-InitiatorPort". Open a command prompt as administrator. vmware - the LUN stores VMware data. WWN zoning is susceptible to unauthorized access, as the zone can be bypassed if an attacker is able to spoof the World Wide Name of an authorized HBA. It is used for connecting and transferring data from hard disk drives to computer systems. Two (and more) servers can share the same LUN at the same time as volumegroup (not as filesystem). name of its next version of Windows server platform to Windows Server 2012. Posted Re: ELM: How to find lun wwn naa? on Security Information and Event Management (SIEM). Select the ESX host in the VI client > Select the Configuration tab > Select Storage Adapters > and on the right hand side the storage adapters are listed. If WWN is not computed, then “Unknown” appears (For example, SCSI). vmware- the LUN stores VMware data; windows- the LUN stores a raw disk type in a single-partition Windows disk using the Master Boot Record (MBR) partitioning style. World wide name of DISK3: 5000CCA378EF2455; World wide name of DISK4: 50014EE2B21AEE7C; To get the correct disk WWN, please refer to /etc/enclosure_0. Good day, everyone! This post highlights the procedure of how to get the WWN on Windows Server 2012. Hi, how can i get this software, mlucli. But this can only be done after ESX has been installed. To do so, you must provide the WWN number of the Linux host and required LUN size to the storage team. How to find WWN for a fibre channel HBA. Run the command inq -winvol. LUN Mapping and Masking Mapping means making devices visible on a storage port. The zone allows a particular server to access that LUN. If you have trouble or bugs in System Center 2012 R2 Virtual Machine Manager you should definitely check out that page. The “ssss” portion of the Port WWN IHHHHHHTOMSssssP can be calculated by the following: Add 70000 (Dec) to the last 6 digits of the DF850 Serial Number. 23, Driver version 7. name of its next version of Windows server platform to Windows Server 2012. Create a new empty text file named nfsone. Masking and zoning are two common practices with LUN storage that affect LUN access. Perform "fcinfo" to find the World Wide Name (WWN). This can be any device that supports read/write operations, such as disk, partitions, logical volumes, files or tape drves: Portal: The IP address and port that a target or initiator uses to establish connections: TPG: The Target Portal Group. Different for each operating system HBA or O/S utility Find WWN using LUN Different for each HBA Storage GUI or CLI Find the device using WWN and LUN. Then map the LUN to both igroup. One of the disks is bad. Here is a short list from 20. If WWN is not computed, then “Unknown” appears (For example, SCSI). What command will be used to scan the LUN on Linux server? Well, in RHEL 6/7 is simple. How to refresh masking database after masking the new luns to a WWN or removing the luns from a WWN (refresh WWN related memory tables with the contents of VCMDB) # symmask -sid 1234 refresh Turn on the flag for different OSs (D for Solaris; C,SC3,OS2007,SPC2 for Windows/VMWare, SPC2 for linux). This article will help Storage admins as well as Sys Admins to find details like port speed, wwn no. Notice: To protect the legitimate rights and interests of you, the community, and third parties, do not release content that may bring legal risks to all parties, including but are not limited to the following: Politically sensitive content; Content concerning pornography, gambling, and drug abuse; Content that may disclose or infringe upon others ' commercial secrets, intellectual properties. Anyone please reply This question is outside the scope of this site and needs to be asked either on the Technet or MSDN forums. PIN authentication (4-16-digit PIN) Windows to go(WTG) compatible Compatibility with any OS - Windows, MAC, Linux, Android, ios. This article outlines the steps required to replace Host Bus Adapter (HBA) cards on servers. Each AIX LUN serial number from pcmpath query device should match with one of the SVC volume UID numbers, as shown in Figure 3. Page 57 Option Description -v jnl[t Displays the JNL status for the local and remote interconnected to the group. We have following utilities in linux to find the hba related information. Specify the WWN of the FC port. Just grep for "port-wwn" in the above command to see only WWPN. Here is a short list from 20. This makes LUNs appear as files in a VMFS volume. I only know for sure how to do this with HP-UX. vmx file) are assigned to the phsyical HBA and the NPIV virtual Port WWN is activated on the SAN switch. Find the device associated to the windows volume T:. iSCSI can be used to transmit data over local area networks (LANs), wide area networks (WANs), or the Internet, and can enable. CD to the directory where inq is downloaded. Compute Module (blade server). Because it requires the host configuration to be. You will need to attach the drives to a non-RAID controller (in LSI speak, "IT mode"). Please share your valuable suggestions and feed back. If it is Solaris, go to /kernel/drv/sd. Windows Server 2008 R2 and 2008 R2 (Service Pack 1) Download the Fibre Channel Information (fcinfo) tool from Microsoft Download Center. The management interface of both the arrays does not display the LUN WWN which I just created. There are a number of identifiers to find out which LUN is which disk, but the only undeniably unique number to find out which disk is which LUN is by using the globally unique wwn number of a LUN. Notice: To protect the legitimate rights and interests of you, the community, and third parties, do not release content that may bring legal risks to all parties, including but are not limited to the following: Politically sensitive content; Content concerning pornography, gambling, and drug abuse; Content that may disclose or infringe upon others ' commercial secrets, intellectual properties. Assume all these will stay as what we knew from Windows Server 8 Beta, you can find some interesting things. There are many ways to find the World Wide Name (WWN) of fibre channel HBA connected to server running windows server operating system. Now we are ready to setup the iSCSI session on the Windows 2012R2 server. If you need additional storage for the Linux host, you must provide the storage team with a WWN number, and they assign a new LUN based on the WWN number. The output is shown in the following screenshot: It is also possible to use the HbaCmd. windows_2008- the LUN stores Windows data for Windows 2008 and 2012 systems. Record the RAID group and level. Create the “LUN” (Volume) Create the Initiator Group with the ESXi Host HBA WWPNs; Create the LUN Mapping Configuration to bind the Volume and Initiator Group together. At the server, launch "Storage Explorer". 1~5 Multi-LUN can be set like (CD, VHD, HDD, Fixed/Removable, Write-Protection) No software or drivers required with our hardware encryption. out (Use swcons to change back. Just something I wanted to share with the community… One of our VMWare Administrators was working with VMWare vendor support in looking at some SAN connection issues and was requesting a report showing the following information: Host, Name, HBAName, Source, Target, LUN, Status, Path, PathSelectionPolicy They could then use this information to further review the…. Host-based zoning is usually referred to as persistent binding or LUN, and is perhaps the least implemented form of zoning. To find and locate the physical devices on the Windows server, run the "inq" or "syminq" command on the kernel. Because it requires the host configuration to be. This is the complete SCSI address (including bus, target, logical unit number (LUN) and PCI port number) through which the MediaAgent attempts to access a device. The WWN is used for the SAS initiator name, and you need the initiator name to associate a LUN with a blade server. Each AIX LUN serial number from pcmpath query device should match with one of the SVC volume UID numbers, as shown in Figure 3. We need “ WWPN Address ” information of HBA card to create zoning on fiber channel switch for assigning and unassign storage to a AIX host. In Windows Server 2008 or 2008 R2, we can use "Storage Explorer" to locate World Wide Name (WWN). How to find out a hard disk model and serial number on Linux? Here are few quick ways. Where do I find the wwn of a disk in Windows / HyperV? That's the question. Download the tool from here:. SchedNumReqOutstanding. Many schools of thought for zoning best practices exist. LUN Masking is important because Windows based servers attempt to write volume labels to all available LUN's. 51G), 6F2(68. This is a GUI based tool that allows firmware upgrades etc and will provide WWN's. Where do I find the wwn of a disk in Windows / HyperV? That’s the question. In first step we have created a LUN. I wrote this script to give me all RDMs in and transcode the LUN serial number from the naa (Network Adress Authority) name. Command to display only World Wide Name. out (Use swcons to change back. This article will help Storage admins as well as Sys Admins to find details like port speed, wwn no. Determine World Wide Name, Serial Number and LUN. Install and run from the below Command Line. 23, Driver version 7. Unmounting a LUN using the command line To unmount a LUN from an ESXi 5. Linux operating system was developed by Linus Benedict Torvalds at the age of 21. Though its a Windows Stuff but its worth mentioning this amazing Tool. Today I needed to find the LUN ID of a NetApp iSCSI LUN. lsscsi is provided by the rpm "lsscsi-0. 5, the fixed value. The Clariion expects that initiators are added in the format :. All LUNs need to map to new array 1334 on FA9A:0 and FA8A:0 WWN of array 1334 FA 9A:0 is 50060482d52dd588. Select the Fibre Channel Ports tab. You can find the WWN's pretty easily using the VI client I believe, either connecting to VirtualCenter or directly to an ESX host. to see new Hyper-V (version 3?) features and enhancements with this name change (from Windows Server 8. If the lun is presented directly to the server, then you can see the lun wwid most easily in multipath -ll, scsi_id on el6 and lsscsi --scsi_id -g on el7, and even ll /dev/disk/by-id/. Storage operations. Maybe you are new in a professional environment where you have to become familiar with new terms like HBA cards and storage via Fiber or others A host bus adapter (HBA) is a circuit board and/or integrated circuit adapter that provides input/output (I/O) processing and physical connectivity between a host system, or server, and a […]. symmask list hba : List the HBA details of the host. lsscsi is provided by the rpm "lsscsi-0. Sample output will be similar to the following: TSM Name ID LUN Bus Port SSN WWN ----- mt0. CD to the directory where inq is downloaded. ZIP) that contains a specific set of drivers and directory structure to be loaded during an Operating System installation to a remote LUN over a SAN. to Windows Server 2012). How to refresh masking database after masking the new luns to a WWN or removing the luns from a WWN (refresh WWN related memory tables with the contents of VCMDB) # symmask -sid 1234 refresh Turn on the flag for different OSs (D for Solaris; C,SC3,OS2007,SPC2 for Windows/VMWare, SPC2 for linux). Record the hard drives in the RAID group and the drive configuration. If present, this element specifies the WWN (World Wide Name) of a virtual hard disk or CD-ROM drive. Sometimes, it can be useful to be able to fetch WWN info before the host has been installed. The PortWWN corresponds to the fibre channel port WWN for the selected device. Find the storage vendor and LUN (df –k and the Solaris format utility) Root login required. The example just about some simple tasks. If WWN is not computed, then “Unknown” appears (For example, SCSI). Inside vmware gui you can find that number in the middle of the vml for the disk. Written by Sam McGeown on Read in about 3 min 535 words Published under VMware. Posted Re: ELM: How to find lun wwn naa? on Security Information and Event Management (SIEM). The host will see the LUN as a “Local Disk. Example: # lslv -l data1. If a LUN is not mapped to a given server, that server cannot see or access the LUN. With older windows operating systems – (Windows 2003) it was recommended that the boot LUN should be on separate SCSI bus from the shared LUNs (to avoid issues with SCSI-bus resets disrupting I/O – causing a BSOD. After LUN expansion what actions need to be done to make the host see the new space After LUN expansion users can use fdisk l command and find the capacity of device such as dev sdn has become larger. ” In storage networking, ”persistent binding” is an option of zoning. Command to display only World Wide Name. The PERC H700 is a RAID controller and doesn't provide a full passthru interface for sg3_utils. This has things like the device serial number (sometimes called a WWN). Its easy to find the naa id of a LUN from windows Guest OS with the help of EMC's Inquiry (inq) tool. 08G), 6FA(68. See the whole switch can use the configuration file so if you say 1234 can see 5678 than the port doesn't matter so if you move device 1234 from physical port 2 to physical port 5 it will still have the same access rights. Also finds the journal ID for each local and. - Remove the upper 1 digit (which is the “S”). This info will be useful for the next steps] - powermt display dev=all - Powermt Pseudo name is equal to the disk number from Diskpart. You can find the LUN ID for each of your additional drives within the Computer Management console on your server. Each LUN is associated with a name and logical unit number (LUN) identifier. Click scan All and the iSCSI software adapter will display the LUN. With older windows operating systems – (Windows 2003) it was recommended that the boot LUN should be on separate SCSI bus from the shared LUNs (to avoid issues with SCSI-bus resets disrupting I/O – causing a BSOD. The zone allows a particular server to access that LUN. to reach the LUN having LUN_id. This is the complete SCSI address (including bus, target, logical unit number (LUN) and PCI port number) through which the MediaAgent attempts to access a device. If you need additional storage for the Linux host, you must provide the storage team with a WWN number, and they assign a new LUN based on the WWN number. The PERC H700 is a RAID controller and doesn't provide a full passthru interface for sg3_utils. Samsung 860 PRO MZ-76P512BW 512GB 2. of HBA card ( for solaris – fcinfo & HP-UX – fcutil) 3. The fcinfo tool is available…. \PHYSICALDRIVE1 DeviceNumber : -1 Accessible : Yes ** Tape Drive Information. Shows the MPIO disk-to-drive mappings for the DSM. Until recently, some variants of physical servers have proven challenging to virtualize—specifically those that are dependent on virtual Fibre Channel storage. 2014: File servers. For LUNs with single VM, this figure is inapplicable, and HBA queue depth is used. This implementation does not call _get_iscsi_properties() to get the properties because cannot store the LUN number in the database. If this is exceeded, commands will be queued in VMkernel. Find the device associated to the windows volume T:. • Mapping File — A VMFS file containing metadata used to map and manage a raw device. Find the (virtual) location of an Ethernet adapter lscfg -l ent1 Find the location codes of all devices in the system lscfg List all MPIO paths for hdisk0 lspath -l hdisk0 Find the WWN of the fcs0 HBA adapter lscfg -vl fcs0 grep Network Temporarily change console output to /console. Also finds the journal ID for each local and. Samsung 860 PRO MZ-76P512BW 512GB 2. Inq –winvol ~show Windows filesystems Inq –dev ## –page0 ~Raw unformatted data on a single device. Also return the iSCSI properties so the initiator can find the LUN. Two (and more) servers can share the same LUN at the same time as volumegroup (not as filesystem). Create the “LUN” (Volume) Create the Initiator Group with the ESXi Host HBA WWPNs; Create the LUN Mapping Configuration to bind the Volume and Initiator Group together. Send-HTMLEmail -InputObject (Get-HBAWin -ComputerName 10. On the VCB proxy / Windows box, I used the Emulex HBAnywhere utility to retrieve the WWPN's of the LUN's that were presented. From there you can use “lscfg -vl fcsN” or “fcstat fcsN” as described in the blog post to get the WWN. 2K SAS Server Hard Drive HUS723020ALS640 0B26315 3. And it’s easier than ever to register! Simply log in to your VMworld account, click on content catalog, find the sessions you want, and add The post VMworld is Almost Here!. There are many ways to find the World Wide Name (WWN) of fibre channel HBA connected to server running windows server operating system. Round Robin. The WWN to register is a combination of the fiber channel port WWN and Compellent Port WWN (i. powermt check_registration ===> Display PowerPath Registration Key / Status. How to get LUN WWN (i. Log in to your server using Remote Desktop. 60060480000290301014533030303130 Device Display Name: EMC Fibre Channel Disk. Vbus: 0-F Target: 0-F LUN: 000-007. Run the command inq -winvol. Some have a unique Node WWN for each of the ports as well. Maybe you are new in a professional environment where you have to become familiar with new terms like HBA cards and storage via Fiber or others A host bus adapter (HBA) is a circuit board and/or integrated circuit adapter that provides input/output (I/O) processing and physical connectivity between a host system, or server, and a […]. I suggest that you highlight and copy the WWN for use in the next step. Started from Windows Server 2012, "Storage Explorer" was removed. 2K SAS Server Hard Drive HUS723020ALS640 0B26315 3. Select FC ports to enable. login to the switch and match the wwn , run switchshow command. Applies To: Hyper-V Server 2012, Windows Server 2012 R2, Windows Server 2012, Hyper-V Server 2012 R2. \PHYSICALDRIVE1 DeviceNumber : -1 Accessible : Yes ** Tape Drive Information. These can be found using the fcinfo command. One of the four virtual Port WWN s (in the order as they appear in the. In first step we have created a LUN. Using Disk Manager Access Disk Manager under "Computer Management" in "Server Manager" or in the command prompt with diskmgmt. This post covers how to provision a LUN for vSphere on an EMC XtremIO brick. 2014: File servers. I wrote this script to give me all RDMs in and transcode the LUN serial number from the naa (Network Adress Authority) name. But it takes 5 minutes googling to understand that the main difference is that zoning is configured on a SAN switch on a port basis (or WWN) and masking is a storage feature with LUN granularity. One solution is to use HBAs that support LUN mapping and will automatically re-assign the LUN IDs as appropriate. login into the server and find the wwn no. Any suggestions/tricks will be appreciated. How to find WWN for a fibre channel HBA. LUN Masking is important because Windows based servers attempt to write volume labels to all available LUN's. When there are multiple LUNs connected to a server, you might want to view information about a specific LUN by providing the logical name of the LUN as shown. Then, click "connect luns. Round Robin. This section describes how to view the detailed information about a virtual LUN. In windows 2008/2012 this is not an issue, boot LUNS can share the same bus/path). Let’s first setup the CHAP secret( This is the outbound password that was setup on the SVM) Set the Initiator chap secret. purestorage. 3PAR-cluster cli% admitpd At the end, tunesys is necessary to make the proper layout of chunklets within CPGs. conf hw_addr=00:08:9B:CB:A3:EA QNAP=TRUE mirror=0 hal_support=yes sm_v2_support=yes pd_dev_wwn_50014EE25C0D43B9=0×1 pd_dev_wwn_5000C5004EE02CCB=0×2 pd_dev_wwn. The card doesn't attach Drive 1 to port 1 sata 1, instead it attaches Drive 1 to which ever drive is detected first. In Windows Server 2003, you have to install "Fibre Channel Information Tool". Vbus: 0-F Target: 0-F LUN: 000-007. Use the PowerShell command, Get-WmiObject to retrieved the information in Windows Server 2012. Create a CSV File of LUN Objects and Attributes. On Esxi you can easily find this by going to Configuration > Storage Adapters and then selecting the storage adapter where you want the WWN from. windows_gpt- the LUN stores Windows data using the GUID Partition Type (GPT) partitioning style. 2K SAS Server Hard Drive HUS723020ALS640 0B26315 3. Sample output will be similar to the following: TSM Name ID LUN Bus Port SSN WWN ----- mt0. Create a NTFS security style qtree in the volume. On the SAN Switch, use command #show fcns database which lists all the WWPN of all the vHBA Host’s Port, NPV WWN of Fabric Interconnect, WWN of EMC Storage Processor (SP) HBA without the NPIV WWPN of the VM (that we generated before) 5. That is, every server sees the disk space on a SAN array which is accessed as its own hard drive. Supported OS: Windows 7, 8/8. symaccess -sid 1234 -type initiator -name Host1 create -wwn 1000000000000001 Creates and initiator group called Host1 by adding the specified wwn. netware - the LUN stores NetWare data. I was hoping I could just get a quick list to confirm a particular LUN was visible on that machine. If the host systems using both FC and iSCSI connections to the same LUN, we have to create two igroup: One for FC and one for iSCSI. Determine World Wide Name, Serial Number and LUN. Info in /proc/scsi/scsi. Check FCINFO (Fibre Channel Information Tool) for windows 2003 & windows 2000 servers. lsscsi is provided by the rpm "lsscsi-0. - CMD > Diskpart > select disk X > Detail disk [note LUN ID and Disk number. This info will be useful for the next steps] - powermt display dev=all - Powermt Pseudo name is equal to the disk number from Diskpart. Though its a Windows Stuff but its worth mentioning this amazing Tool. Open a 3PAR CLI connection to the secondary 3PAR array and in this CLI environment, you will issue a setvv command. The following article will help you find the WWN number of a Linux host. Awhile back a guy at the San Antonio VMUG asked the technical group how you could get the actual LUN UUID for a particular Datastore. How to find WWN for a fibre channel HBA. The former will show the local WWN, the latter the remote WWN. Find the (virtual) location of an Ethernet adapter lscfg -l ent1 Find the location codes of all devices in the system lscfg List all MPIO paths for hdisk0 lspath -l hdisk0 Find the WWN of the fcs0 HBA adapter lscfg -vl fcs0 grep Network Temporarily change console output to /console. Some of the important key notes about this. All LUNs need to map to new array 1334 on FA9A:0 and FA8A:0 WWN of array 1334 FA 9A:0 is 50060482d52dd588. Create a CSV File of LUN Objects and Attributes. To find WWN in Windows Server 2012 or 2012 R2, we can use PowerShell to perform "Get-InitiatorPort". 254) -Subject "HBA Info". Though when I try to configure the devices in NBU device configurat. - Remove the upper 1 digit (which is the “S”). In Windows Server 2008 or 2008 R2, you can use "Storage Explorer" to show the WWN. I am assuming LUN_id is 0, but issuing a 0 in the bootluncfg doesn't work so I was wondering if the LUN id is easily obtainable on the Compellent Admin console. Use the PowerShell command, Get-WmiObject to retrieved the information in Windows Server 2012. 3PAR-cluster cli% showpd -i After that use admitpd command to make new disk operational for system. The SP use soft zoning to control LUN visibility per WWN. Once installed open a Command Prompt or Windows PowerShell session and run the tool. When you use the zoning off of WWN you get a greater range of flexibility. The host will see the LUN as a “Local Disk. the host side I need to find out the lun wwn for the luns I have created on both the systems. For LUNs with single VM, this figure is inapplicable, and HBA queue depth is used. Info in /proc/scsi/scsi. Each LUN is associated with a name and logical unit number (LUN) identifier. The Driver Update Disk (DUD) is an extractable image (. - CMD > Diskpart - List disk [Disk number from Diskpart is equal to the disk number from disk management GUI] - CMD > Diskpart > select disk X - CMD > Diskpart > select disk X > Detail disk [note LUN ID and Disk number. The Fibre Channel Switch uses hard zoning, which controls SP visibility on a per switch basis as well as LUN masking. Find a specific datastore. The LUN_Number would typically be zero for standard disks and tapes. What is a World Wide Name (WWN)? A World Wide Name, or WWN, is a 64-bit address used in fibre channel networks to uniquely identify each element in a Fibre Channel network. If this is exceeded, commands will be queued in VMkernel. Until recently, some variants of physical servers have proven challenging to virtualize—specifically those that are dependent on virtual Fibre Channel storage. Maybe you are new in a professional environment where you have to become familiar with new terms like HBA cards and storage via Fiber or others A host bus adapter (HBA) is a circuit board and/or integrated circuit adapter that provides input/output (I/O) processing and physical connectivity between a host system, or server, and a […]. Then map the LUN to both igroup. LUN masking is a method of restricting which devices can view, send, and receive commands to specific LUNs on a storage controller. For LUNs with single VM, this figure is inapplicable, and HBA queue depth is used. Use the newly added disk to extend an existing Volume Group. To check the HBA cards installed on your system, check lspci. Scsi Port : Scsi1 Base Bus : 0 Base Target : 0 Base Lun : 0 Vendor : HP Model : Ultrium 5-SCSI. There are many ways to find the World Wide Name (WWN) of fibre channel HBA connected to windows server operating system 1. Choose another data disks and repeat the same steps. How to find the WWN of your installed Fibre HBA in a windows server without having the Vendor tools installed. The disks have the name QEMU HARDDISK instead of the real name WDC WD40EFRX-68N32N0 (see below) i guess that LUN passthrough will enable smart access to the disks from the VM. if you want it to be aware of the wwn, it might have ot be connected through the vm itself. Find the NAA id of the LUN associated to the Device PHYSICALDRIVE4. In Windows Server 2003, you have to install "Fibre Channel Information Tool". How to get lun wwn id on windows server 2012. Windows 2003/2000. In this post I will explain what NetBackup SAN Client is and how to configure it. 254) -Subject "HBA Info". In Windows this translates to a “location” and “target”. First find out how many bus adapters you have: [[email protected] ~]# ls /sys/class/fc_host/ host0 host1. Vircom launches first Windows- based email. We need “ WWPN Address ” information of HBA card to create zoning on fiber channel switch for assigning and unassign storage to a AIX host. Owner: default=SP B, current=SP B – This indicates that the default (and current) owner for this LUN is storage processor SP B. Title: The NV driver fails to attach or is not installed automatically - how to use sgen instead Date: 28/06/06 NV Version: 7. Round Robin. 8Gbit Fibre Channel connection for storage 450 meters (1476 feet) from switch. I recommend combining this script with Send-HtmlEmail function. Now is the time to save the information:. Check this with showpd -i command. In Windows Server 2008 or 2008 R2, you can use "Storage Explorer" to show the WWN. In order to use NPIV, you have to add RDM - Raw Device Mapping to VM. The following article will help you find the WWN number of a Linux host. See the whole switch can use the configuration file so if you say 1234 can see 5678 than the port doesn't matter so if you move device 1234 from physical port 2 to physical port 5 it will still have the same access rights. LUN storage can improve virtual machine performance. Now, when doing an ls -l on /dev/disk/by-path, she recognized parts of the filesnames as identifiers corresponding to the wwn's of the individual paths (All 140+). Enter the INQ utility, from EMC. There are many ways to find the World Wide Name (WWN) of fibre channel HBA connected to windows server operating system. Windows, ACKs, ordering, etc. Assign servers to the security group. Get-Disk -Number 17 | Select UniqueId. Having a single_image cfmode will increase the amount paths to a lun and will also change the wwpn on a host (As they share a wwpn) HBYAnywhere is used to find information about emulux HBA’s Standby mode is only supported by windows and solaris hosts. 0 host using the. Real time military grade AES-XTS 256-bit hardware encryption. symmask -sid 1234 refresh : Refresh the VCM Data Base after a masking and unmasking operation. Any help is appreciated. windows_gpt- the LUN stores Windows data using the GUID Partition Type (GPT) partitioning style. Once installed open a Command Prompt or Windows PowerShell session and run the tool. iSCSI is an Internet Protocol (IP)-based storage networking standard for linking data storage facilities. Run the command inq -winvol. It’s available via public FTP here. In order for the device configuration wizard to properly configure the location of the drives within the library, the serial number is used to correlate the tape device location on the attached host and the bay within the library. Go to RUN -> cmd. The command esxcli storage nmp device list lists the LUN multipathing information: naa. fdisk is a dialog-driven program for creating and manipulating partition tables whereas sfdisk is a script-oriented tool for partitioning any block device. Solaris OS. You create the LUN and assign it to the WWN of the bootable adapter, and then the host's adapter will see the LUN. Now we need a host that can access the LUN. Shield out direct LUN operations; Can leverage advanced Windows storage features – CSV cache, SSD tiering, etc. It must be composed of 16 hexadecimal digits. ZIP) that contains a specific set of drivers and directory structure to be loaded during an Operating System installation to a remote LUN over a SAN. In Windows Server 2003, you have to install "Fibre Channel Information Tool". This implementation does not call _get_iscsi_properties() to get the properties because cannot store the LUN number in the database. Zoning and masking terms are often confused by those who just started working with SAN. The famous FC Host Bus Adapters are QLogic, Emulex, Brocade, Cisco, etc. This tool is to discovery the SAN resources and configuration information on your Fibre Channel SAN. No comments: windows (24) xen (2) Do You Need Help?. Few model dependent utilities are: HBAnyware utility (Emulex) SANsurfer utility (Qlogic) For any other model of HBAs, the Fibre Channel Information Tool utility (FCINFO. Hi Friends Welcome to my YouTube Channel. Written by Sam McGeown on Read in about 3 min 535 words Published under VMware. symmask -sid 1234 refresh : Refresh the VCM Data Base after a masking and unmasking operation. Get-Disk -Number 17 | Select Un. Check FCINFO (Fibre Channel Information Tool) for windows 2003 & windows 2000 servers. Find the device associated to the windows volume T:. The LUN_Number would typically be zero for standard disks and tapes. Usually the proper naming convention shall help identifying this but in historical grown environments you might run into the same problem and a simple one-line returns the proper. How can I get WWN and LUN id from windows server 2008 and 2012 r2. Maybe you are new in a professional environment where you have to become familiar with new terms like HBA cards and storage via Fiber or others A host bus adapter (HBA) is a circuit board and/or integrated circuit adapter that provides input/output (I/O) processing and physical connectivity between a host system, or server, and a […]. if you want it to be aware of the wwn, it might have ot be connected through the vm itself. Unmounting a LUN using the command line To unmount a LUN from an ESXi 5. <WWN>'. 5, the fixed value. systool lsscsi sg_map Using "systool" we can find the WWN of the HBA's installed in the linux host. Customer requested to increase the windows volume T:. But this can only be done after ESX has been installed. Click scan All and the iSCSI software adapter will display the LUN. How to check WWN and Multipathing on Windows Server There are many ways to find the World Wide Name (WWN) of fibre channel HBA connected to windows server operating system Windows 2003/2000. Same LUN ID for a volume within a host (so each path shows the same LUN ID for a volume) and also having the same LUN IDs for a volume on different hosts. Compute Module (blade server). it will provide lines like wwn-0x60050768018087935800000000000537 ->. Base Lun : 0 Vendor : HP Model : Ultrium 5-SCSI Firmware : I6GW SerialNumber : HUJ5604A9B WWN : 50014380062b6b4f Access Path : \\. This post covers how to provision a LUN for vSphere on an EMC XtremIO brick. How to check WWN and Multipathing on Windows Server, find wwn on windows 2003, find wwn on windows 2008, fcinfo, storage explorer, Emulex, HBAanywhere, DA: 57 PA: 25 MOZ Rank: 65 Mapping hdisk# to LUN ID on AIX Server. 5; How to run Wireshark as a Windows service; XenApp 6 for Windows Server 2008 R2; Citrix Upgrade Planning from Xenapp 6 or 6. See screenshot bellow. This has things like the device serial number (sometimes called a WWN). Find HBA and WWN Information on Windows using WMI (Updated June 2015) Find the WWN Information in order to Map storage etc. Many schools of thought for zoning best practices exist. If you need additional storage for the Linux host, you must provide the storage team with a WWN number, and they assign a new LUN based on the WWN number. The following powershell cmdlets can be used to achieve this. And while this is important mapping information to have backed up in case of a blowup like the one you had, on a VM with vmfs underneath (and the lun wwid hidden. Symmaskdb -sid XXX -wwn 1000000c94d35cd -dir 6 d -p 1 add devs 27CA -nop. On Esxi you can easily find this by going to Configuration > Storage Adapters and then selecting the storage adapter where you want the WWN from. However, this is not the same for all HBA manufacturers. Hi there!Main-Problem:Fantec QB-35US3-6G (external storage box with 4 bays) only recognizes one drive; all other drives from the box are not available. symaccess -sid 1234 -type initiator -name Host1 create -wwn 1000000000000001 Creates and initiator group called Host1 by adding the specified wwn. Need to remove a DM multipath device, how to find a wwid of the multipath device in RHEL? How to find the LUN ID / World Wide Name (WWN) of a disk? How to find the Lun ID for storage disks How Can I Find My Host Assigned Lun ID? Unable to find my host assigned lun ID What is the command to match the lun ID with the disk?. e LUN mapped from a storage box say Symmetrix or clariion) in Solaris. iSCSI connections : we can create an iSCSI igroup using the iSCSI node name of the host. It's easy enough to get lun numbers if I go into disk management and right-click each volume, but I have around 30 volumes. 9 >) Windows. 3PAR-cluster cli% admitpd At the end, tunesys is necessary to make the proper layout of chunklets within CPGs. Base Lun : 0 Vendor : HP Model : Ultrium 5-SCSI Firmware : I6GW SerialNumber : HUJ5604A9B WWN : 50014380062b6b4f Access Path : \\. This is a GUI based tool that allows firmware upgrades etc and will provide WWN's. Storage operations. These can be found using the fcinfo command. This article describes how to rescan QLogic Host Bus Adapter (HBA) for new Logical Unit Numbers (LUNs), and query the HBA or ISCSI in XenServer 6 and later. In first step we have created a LUN. Extend the volume/LUN from the SAN management console. of HBA card ( for solaris – fcinfo & HP-UX – fcutil) 3. The mostly used for the Host servers like Linux, AIX, UNIX, Windows etc. Seeing that would like an ifconfig. another way to find the wwn is through POST there you can click for HBA Bios and Check the WWN of each HBA. conf hw_addr=00:08:9B:CB:A3:EA QNAP=TRUE mirror=0 hal_support=yes sm_v2_support=yes pd_dev_wwn_50014EE25C0D43B9=0×1 pd_dev_wwn_5000C5004EE02CCB=0×2 pd_dev_wwn. Windows hosts connect directly to FC LUNs that they have access to across the SAN. Some have a unique Node WWN for each of the ports as well. 6) devfsadm (solaris 2. In this example it's "LUN 3" and "PURE. Only the masked wwns can see the LUNs. it should view the lun as a locally presented disk. • Mapping — An abbreviated term for a raw device mapping. 254) -Subject "HBA Info". The following steps explain how to determine the HBA WWN on a Solaris host. A SAN client is a special NetBackup client that can back up large amounts of data rapidly over a SAN rather than a LAN. You can find information about various transport being used in the system such as ATA, Fibre channel (FC), IEEE 1394 (SBP), iSCSI: target only, SCSI Parallel Interface (SPI), Serial Attached SCSI (SAS), SATA, and USB. conf hw_addr=00:08:9B:CB:A3:EA QNAP=TRUE mirror=0 hal_support=yes sm_v2_support=yes pd_dev_wwn_50014EE25C0D43B9=0×1 pd_dev_wwn_5000C5004EE02CCB=0×2 pd_dev_wwn. command that contains various parameters like Port World Wide Name (WWN). msc as a software mirror, or whatever MS's parlance is. Compared to provisioning the same on an EMC Symmetrix VMAX, it is very, very simple. Create LUNs on new array 1334 with same LUN size and LUN raid-type: 1035(8. Proxmox takes care that only one server use a logical volume at one time. A LUN is a single unit of storage that represents a specific storage pool and quantity of Fibre Channel (FC) or iSCSI storage. This makes LUNs appear as files in a VMFS volume. Windows 7 Activation Patch PlusPatch V5 4. 0-435426 on Windows 7 Enterprise. Please share your valuable suggestions and feed back. Once the disk / LUN is made available/visible to the server, the next step is to scan it. This article outlines the steps required to replace Host Bus Adapter (HBA) cards on servers. You will run this utility from DOS, and use the following flag inq -showvol -sym_wwn. to see new Hyper-V (version 3?) features and enhancements with this name change (from Windows Server 8. Port WWN = Port’s node address on HBA. iSCSI can be used to transmit data over local area networks (LANs), wide area networks (WANs), or the Internet, and can enable. exe? i cant find nowhere. login into the server and find the wwn no. Inside of the box, we find just the drive itself. 2014: File servers. This can be any device that supports read/write operations, such as disk, partitions, logical volumes, files or tape drves: Portal: The IP address and port that a target or initiator uses to establish connections: TPG: The Target Portal Group. To find WWN in Windows Server 2012 or 2012 R2, we can use PowerShell to perform "Get-InitiatorPort". How to find World Wide Name (WWN) in Windows Server 2012 … 5/31/2006 · Fibre Channel Information Tool (fcinfo). The local fibre channel card has a WWN. These can be found using the fcinfo command. The -mt 15 parameter specifies themaximum target ID that is in use on any SCSI bus (or bound to a fibre channel device). setvv -wwn. Unfortunately, they aren’t there. In Windows Server 2003, you have to install "Fibre Channel Information Tool". On the SAN Switch, use command #show fcns database which lists all the WWPN of all the vHBA Host’s Port, NPV WWN of Fabric Interconnect, WWN of EMC Storage Processor (SP) HBA without the NPIV WWPN of the VM (that we generated before) 5. Unmounting a LUN using the command line To unmount a LUN from an ESXi 5. 9 >) Windows. 2K SAS Server Hard Drive HUS723020ALS640 0B26315 3. Specify the WWN of the FC port. Perform "fcinfo" to find the World Wide Name (WWN). " Find the LUN you created earlier under one of the storage processors, then click "Add" to add it to the storage group associated with your server. hpux - the LUN stores HP-UX data. AutoIt v3 is a freeware BASIC-like scripting language designed for automating the Windows GUI and general scripting. The WWN id can be identified both from the VI client (Configuration -> Storage Adapters) and from the service console. PIN authentication (4-16-digit PIN) Windows to go(WTG) compatible Compatibility with any OS - Windows, MAC, Linux, Android, ios. The local fibre channel card has a WWN. VMware shows it as naa. Find HBA and WWN Information on Windows using WMI (Updated June 2015) Find the WWN Information in order to Map storage etc. Open a 3PAR CLI connection to the secondary 3PAR array and in this CLI environment, you will issue a setvv command. Anyone please reply This question is outside the scope of this site and needs to be asked either on the Technet or MSDN forums. Do the LUN masking on the storage system so the initiator can access the LUN on the target. The OS distinguishes each LUN using more than just the LUN Id. Shows the MPIO disk-to-drive mappings for the DSM. On the SAN Switch, use command #show fcns database which lists all the WWPN of all the vHBA Host’s Port, NPV WWN of Fabric Interconnect, WWN of EMC Storage Processor (SP) HBA without the NPIV WWPN of the VM (that we generated before) 5. Different for each operating system HBA or O/S utility Find WWN using LUN Different for each HBA Storage GUI or CLI Find the device using WWN and LUN. Open a CMD window. " Find the LUN you created earlier under one of the storage processors, then click "Add" to add it to the storage group associated with your server. Untuk menampilkan world wide name (WWN) pada windows server ada 2 cara, …How to find World Wide Name (WWN) in Windows Server 2008 and 2008 R2. This is Introduction Video of VMware VCP 5. Below are some powershell command variants. Few model dependent utilities are: HBAnyware utility (Emulex) SANsurfer utility (Qlogic) For any other model of HBAs, the Fibre Channel Information Tool utility (FCINFO. Poster Companion Reference: Hyper-V Storage Page 5Consider a virtual environment. ) iSCSI Protocol Data Unit (PDU): Provides ordering and control information. See the whole switch can use the configuration file so if you say 1234 can see 5678 than the port doesn't matter so if you move device 1234 from physical port 2 to physical port 5 it will still have the same access rights. CD to the directory where inq is downloaded. 254) -Subject "HBA Info". How to get lun wwn id on windows server 2012 go to powershell and run below mentioned command. However, as stated in the Release Notes the Fibre Channel Information Tool does not have to be installed to work correctly. For LUNs with single VM, this figure is inapplicable, and HBA queue depth is used. For example, if the LUN address is defined on the director as F0 in hex (240 decimal), the host will discover the device as LUN 240. if you want it to be aware of the wwn, it might have ot be connected through the vm itself. iSCSI connections : we can create an iSCSI igroup using the iSCSI node name of the host. All modern hardware supports zoning and masking. Perform "fcinfo" to find the World Wide Name (WWN). To connect a Windows host to a FC LUN: Configuring a Windows Server 2003 host to connect to a FC LUN; Configuring a Windows Server 2008 R2, Windows Server 2012, Windows7, or Windows 8 host to connect to a FC LUN. symmask list hba : List the HBA details of the host. How to get LUN WWN (i. It is used for connecting and transferring data from hard disk drives to computer systems. VMworld 2020 is only a few weeks away! If you are registered to attend, the VMworld 2020 scheduling feature is your ticket for reserving a spot in the hottest sessions. setvv -wwn. Base Lun : 0 Vendor : HP Model : Ultrium 5-SCSI Firmware : I6GW SerialNumber : HUJ5604A9B WWN : 50014380062b6b4f Access Path : \\. 254) -Subject "HBA Info". Info in /proc/scsi/scsi. powermt display dev=emcpowera – Display specific LUN. The SP use soft zoning to control LUN visibility per WWN. login to the switch and match the wwn , run switchshow command. Once the disk / LUN is made available/visible to the server, the next step is to scan it. Once installed open a Command Prompt or Windows PowerShell session and run the tool. and also, what´s the password needed for storage pool recovery and lun recovery?. Run the command inq -winvol. NOTE: Mapping varies depending on the OS of the server, the ports used in frame for HP-UX servers volume addressing is enabled and hence the Mapping should details of vbus, target and lun whereas for Windows servers just the Lun info while mapping is enough. How to find out a hard disk model and serial number on Linux? Here are few quick ways. Re: to find wwn number Or, if you have access to the SAN switches the hosts are connected to, run a "switchshow" (Brocade) or a "show flogi database" (Cisco) and look at the wwn and the port your host is attached to. Inside of the box, we find just the drive itself. If you have trouble or bugs in System Center 2012 R2 Virtual Machine Manager you should definitely check out that page. How to find the WWN of your installed Fibre HBA in a windows server without having the Vendor tools installed. SchedNumReqOutstanding. Masking means not allowing all attached (= zoned) hosts to see everything on that storage port. fcinfo command does give the Target port wwn but what i'm looking for is the LUN WWN. This name is then used to grant and restrict access to other components of the SAN. To do so, you must provide the WWN number of the Linux host and required LUN size to the storage team. Send-HTMLEmail -InputObject (Get-HBAWin -ComputerName 10. The -ml 1 parameter specifies the maximum target LUN that is in use on any SCSI bus (or by a fibre channel device). it will provide lines like wwn-0x60050768018087935800000000000537 ->. How can I get WWN and LUN id from windows server 2008 and 2012 r2. Linux is one of the world’s most powerful and popular operating system. To determine an HBA WWN, you must first display devices attached to that host. (2 Replies). ” In storage networking, ”persistent binding” is an option of zoning. Find VM Attached RDM By WWN; Find VM Datastore By WWN; Check If A. EXE) can be used. The Clariion expects that initiators are added in the format :. Create a CSV File of LUN Objects and Attributes. The zone allows a particular server to access that LUN. Base Lun : 0 Vendor : HP Model : Ultrium 5-SCSI Firmware : I6GW SerialNumber : HUJ5604A9B WWN : 50014380062b6b4f Access Path : \\. You will run this utility from DOS, and use the following flag inq -showvol -sym_wwn. Scsi Port : Scsi1 Base Bus : 0 Base Target : 0 Base Lun : 0 Vendor : HP Model : Ultrium 5-SCSI. LUN in storage terms is referred to as serial-hex of LUN. In Control Panel, you’ll find the “Mail” item added by Outlook: You click it and get: You can either click “Email Accounts” to add the other Exchange account to the last profile you have in Outlook, or click “Show Profiles” to choose which profile to add the account to (probably you’ll delete the other profile after that). Before you can configure IBM Tivoli Storage Manager for server-free data movement, you must first identify and record the world wide name, serial number, and LUN of each disk device and tape drive used, and the world wide name and serial number of the data mover. Two (and more) servers can share the same LUN at the same time as volumegroup (not as filesystem). The SP use soft zoning to control LUN visibility per WWN. Because it requires the host configuration to be. If you have trouble or bugs in System Center 2012 R2 Virtual Machine Manager you should definitely check out that page. Brocade port error show. The OS distinguishes each LUN using more than just the LUN Id. In Windows Server 2008 or 2008 R2, you can use "Storage Explorer" to show the WWN. However, this is not the same for all HBA manufacturers. e LUN mapped from a storage box say Symmetrix or clariion) in Solaris. [~] # cat /mnt/sdg_root/. [email protected] # prtpicl -v -c scsi-fcp | grep -i port-wwn. The zone allows a particular server to access that LUN. Zoning and LUN masking can limit the access of devices at this point. Started from Windows Server 2012, "Storage Explorer" was removed. To determine an HBA WWN, you must first display devices attached to that host. To enable auditing access on individual files and directories, complete the following steps on the Windows administration host. to reach the LUN having LUN_id. and is not endorsed or sponsored by the Storage Networking Industry Association (SNIA). The famous FC Host Bus Adapters are QLogic, Emulex, Brocade, Cisco, etc. Open the share to this new qtree via windows, and select the nfsaudit file. You will run this utility from DOS, and use the following flag inq -showvol -sym_wwn. Having a single_image cfmode will increase the amount paths to a lun and will also change the wwpn on a host (As they share a wwpn) HBYAnywhere is used to find information about emulux HBA’s Standby mode is only supported by windows and solaris hosts. Log in to your server using Remote Desktop. “x” Represents the SCSI controller and “y” is the LUN id. You have the new Data store available for hosting VMs. In order to use NPIV, you have to add RDM - Raw Device Mapping to VM. 5; Procedure to find out WWN information from ILO: XenApp 6 for Windows Server 2008 R2; Citrix Upgrade Planning from Xenapp 6 or 6. Windows Server 2012R2 setup. By target WWN I mean the storage array's WWN. I've found a number of wmi classes that deal with MPIO, but none so far that offer the LUN number(s) for a particular disk. Compute Module (blade server). Add a Virtual/Secondary IP Address on Windows. Open the share to this new qtree via windows, and select the nfsaudit file. login to the switch and match the wwn , run switchshow command. Some have a unique Node WWN for each of the ports as well. How can I get WWN and LUN id from windows server 2008 and 2012 r2. These target IDs follow the SCSI naming convention. Select the Configuration tab -> Storage Adapters. In the Start menu, right click on Computer, and then select Manage from the pull out menu. Before you can configure IBM Tivoli Storage Manager for server-free data movement, you must first identify and record the world wide name, serial number, and LUN of each disk device and tape drive used, and the world wide name and serial number of the data mover. It is used for connecting and transferring data from hard disk drives to computer systems. Only the masked wwns can see the LUNs. Node WWN = HBA cards’s node address, this is physically burnt on the card. Adding a new disk to the system can be local or from storage.